Although BS EN 61439 is still to be released A & T Enclosures have commenced adoption of the new standard by successfully type testing at IPH, Berlin in accordance with IEC 61439-2.  By meeting the new standards, ATE are able to offer compliant assemblies giving customers confidence at a time of transition.

IEC 60439-1 for low voltage and switchgear assemblies dealt with type-tested assemblies (TTA) and partially type tested assemblies (PTTA) and covered a varied range.

The standard focussed on TTA meaning that changes in design or substitution of components compromised compliance and even at best, was often left open to interpretation. 

The new standard IEC 61439-2, for power switchgear and controlgear assemblies has removed the two type tested definitions and offers clear guidance for variations to the tested design, by use of design rules and calculation.  Not only does this method offer assurance of compliance with the requirements it reduces design variation costs and optimises the manufacturing process.

The recent testing involved short circuit tests of devices, main busbars, a neutral test and a protective circuit test. In addition, an IP test was successfully completed.  Further tests are planned including heat rise tests and, in line with the new requirements some data obtained from previous tests to BS EN 604389-1 will be re-used.

By working towards fully complying with BS EN 61439-2, once the standard is released, ATE will be able to offer their clients peace of mind that the assemblies supplied can be verified with certification to confirm this. 

ATE are confident that being ahead of the game and offering the most up to date certification will strengthen your own sales.

For further information please contact:

Mr Tim King
A & T Enclosures Limited
Unit A, Grazebrook Industrial Park
Peartree Lane
Dudley
West Midlands
DY2 0XW

Tel: 01384 212316
Fax: 01384 238744
E-mail:


Other News

ATE RAISES THE BAR

A new busbar design from Dudley based A & T Enclosures looks set to raise standards in enclosure quality and reliability by passing stringent international standards.

The enclosure and fabrication specialists have successfully tested their latest system in accordance with IEC guidelines.

More...

 

       Good engineers that can fill in the gaps.....
       Cheaper and quicker. To be visited more often.....
Unit A, Grazebrook Industrial Park, Peartree Lane, Dudley, West Midlands, DY2 0XW
T: 01384 212316 F: 01384 238744 e: sales@at-enclosures.co.uk